Home

  
 
 

Search Knowledge Base


Knowledge Base Web View
Total Records: 103
ID Title Type Of Article
259 
Bay Dermatology Data-Center and Citrix Migration to 2X RAS on Data-Tech Cloud Services Case Study
577 
Access Health Care Physicians, LLC Internet Security and Performance Optimization Case Study
578 
Columbia Restaurant Group Migration Premise to the Cloud Case Study
579 
Data-Tech and Level 3 Communications Create Unique Partnership Case Study
580 
Managed Security Services recovers stolen medical equipment for client Case Study
581 
Property Management IT Services Increases Productivity for Realtor Case Study
582 
Hooters Hotel & Casino Las Vegas – Technology Upgrade and Rollup Case Study
583 
Aaneel Infotech VDI Programmers Project – How to use local USA resources and leverage oversees talent Case Study
584 
Data-Tech Provides Versa Managed Services for Tampa Gastro Group Case Study
585 
Seminole Hard Rock Casino – PCI Compliance for 5 years of data backup on tape Case Study
586 
QuickBooks Multi-Client Management Solution for Renaissance Consulting Case Study
587 
Voice over IP Phone System as a Business Management Tool Case Study
588 
Web Enable Applied Systems Technology Software and Consolidate Management Case Study
589 
Why is Data-Tech unique in an industry full of technology service providers? Case Study
590 
Tew and Associates Migration to Managed Services and Cloud Solution Case Study
591 
Data-Tech Chooses Kaseya Over Major Competitor After Three Month Evaluation Case Study
592 
Kaseya VSA Over Other Tools What it Means for Our Clients Case Study
593 
Emergency Services Turn to 3CX Voice Over IP Phone System after Hurricane Strikes Case Study
594 
The solution was extremely reliable and the process couldn’t be simpler. Case Study
595 
What value does Data-Tech bring to a Cloud Provider Partnership? Case Study
596 
Cyber Security and My Cloud Applications: Am I safe? Case Study
597 
Hyper-Converged Threat Initiative IT Security Strategy Case Study
598 
Dynamic Resource Allocation Strategy Workforce Management Case Study
599 
Consumption Marketing a function Consumption Economics: The New Rules of Marketing Case Study
309 
Florida Uniform Trade Secrets Act 2018 Company Policy
Add New  Records per page  1 of 5   
Engage Knowledge Base Web View         How To          Print
Title Browser Emulation Settings in the Registry allows IE version for specific applications      
Resolution
The table below (source) lists the currently supported emulation versions at the time of writing. As you can see, it's possible to emulate all "recent" versions of Internet Explorer in one of two ways - either by forcing a standards mode, or allowing !DOCTYPE directives to control the mode. The exception to this dual behaviour is version 7 which is as is.
 
According to the documentation the IE8 (8000) and IE9 (9000) modes will switch to IE10 (10000) mode if installed. The documentation doesn't mention if this is still the case regarding IE11 so I'm not sure on the behaviour in that regard.
 
Value Description
11001 Internet Explorer 11. Webpages are displayed in IE11 edge mode, regardless of the !DOCTYPE directive.
11000 IE11. Webpages containing standards-based !DOCTYPE directives are displayed in IE11 edge mode. Default value for IE11.
10001 Internet Explorer 10. Webpages are displayed in IE10 Standards mode, regardless of the !DOCTYPE directive.
10000 Internet Explorer 10. Webpages containing standards-based !DOCTYPE directives are displayed in IE10 Standards mode. Default value for Internet Explorer 10.
9999 Windows Internet Explorer 9. Webpages are displayed in IE9 Standards mode, regardless of the !DOCTYPE directive.
9000 Internet Explorer 9. Webpages containing standards-based !DOCTYPE directives are displayed in IE9 mode. Default value for Internet Explorer 9.
8888 Webpages are displayed in IE8 Standards mode, regardless of the !DOCTYPE directive.
8000 Webpages containing standards-based !DOCTYPE directives are displayed in IE8 mode. Default value for Internet Explorer 8
7000 Webpages containing standards-based !DOCTYPE directives are displayed in IE7 Standards mode. Default value for applications hosting the WebBrowser Control.
 
Setting the emulation version is very straightforward - add a value to the registry in the below key containing the name of your executable file and a value from the table above.
 
HKEY_LOCAL_MACHINE (or HKEY_CURRENT_USER)
   SOFTWARE
      Microsoft
         Internet Explorer
            Main
               FeatureControl
                  FEATURE_BROWSER_EMULATION
                     yourapp.exe = (DWORD) version
Vendor *
Web Link https://www.cyotek.com/blog/configuring-the-emulation-mode-of-an-internet-explorer-webbrowser-control
Date Entered 10/10/2019
You Tube Link
Type Of Article How To
Article ID 675


  Copyright    Lietz Development, Inc. 1996. All Rights Reserved.