Home

  
 
 

Search Knowledge Base


Knowledge Base Web View
Total Records: 103
ID Title Type Of Article
1381 
Work Order Task Details Updates to Main Work Order How To
1105 
Word for Windows Training Tips and Tricks Training Resources
474 
Windows Startup Folder Location Support
712 
Windows 10 multiple display - windows are moved and resized on display power cycle or sleep Support
257 
Windows 10 1803 Redstone 4 Upgrade Support
589 
Why is Data-Tech unique in an industry full of technology service providers? Case Study
595 
What value does Data-Tech bring to a Cloud Provider Partnership? Case Study
588 
Web Enable Applied Systems Technology Software and Consolidate Management Case Study
587 
Voice over IP Phone System as a Business Management Tool Case Study
96 
View emails of deleted employees with GFI Email Archiver Support
236 
Using DocuSign for Quotes in Scorpion Workflow
671 
Use Eversign with Engage for Digital Signatures on Quotes, Work Orders, Invoices and More How To
23 
Upgrading Xp Pro to Windows 7 application and all Support
778 
TPM Installed on Cheetah requires correct BIOS Version How To
594 
The solution was extremely reliable and the process couldn’t be simpler. Case Study
590 
Tew and Associates Migration to Managed Services and Cloud Solution Case Study
120 
Telnet to device not working externally but does internally Support
319 
Submit a Ticket on Scorpion Interactive - Client Facing How To
258 
SOPHOS XG Licensing Guide Support
1323 
Sophos MDR Managed Detection and Response Sales Collateral
1404 
Setup Engage BMS Launch Batch File for Engage Startup How To
1024 
Setup Access to Compliance File Manager on SI Portal How To
585 
Seminole Hard Rock Casino – PCI Compliance for 5 years of data backup on tape Case Study
101 
RETRIEVE AN ONT OR MODULE INVENTORY REPORT IN AXSVISION How To
1317 
Reenabling Home Page or Web Page Views for Outlook Folders How To
Add New  Records per page  1 of 5   
Engage Knowledge Base Web View         Support          Print
Title Converting ASYNCC to ASYNCD Cards in an OLT      
Resolution

Symptoms:
How to change an ASYNC C Card to an ASYNC D Card DESCRIPTION: This document outlines the process of converting an OLT from ASYSC System Controllers to ASYSD System Controllers. Note: This procedure assumes that the OLT has ASYSC System Controllers in both slots SYS-A and SYS-B and that the System Controller in SYS-A is the Active System Controller. Note: This procedure is designed for OLT R7.3.0.1 software. Note: Please follow proper ESD protection when working with the OLT hardware.
Possible Cause:
Na


Resolution:
July 18, 2011 1 FTTP-TB-2011-001 February 21, 2011 Technical Bulletin OLT Converting ASYSC System Controllers to ASYSD System Controllers for R7.3 FTTP-TB-2011-003 For Markets: All FTTP Worldwide Customers Affected Software: OLT R7.3.0.1 and higher Affected Hardware: AXS2200 chassis, AXS1800 chassis MOTOROLA and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings, LLC. All other trademarks are the property of their respective owners. © 2011 Motorola Mobility, Inc. All rights reserved. 2 PROCEDURE: 1. Connect a console cable to the Active System Controller and connect a second console cable to the Standby System Controller. Open a terminal session for each console cable and log the data to a file. The settings for the serial ports are as follows: Baud Rate: 9600 Data: 8 Bit Parity: None Stop: 1 Flow Control: None 2. In the OLT CLI, type the following command to enable autonomous messages: AXS> set chassis autonomous on 3. Create an OLT Database backup using AXSVision. Open the AXSVision Software Manager application. Create and run an OLT Backup Task. Make sure that the “Delete backup on FLASH upon completion” is NOT checked. See Figures 1, 2, 3 below. Figure 1 – Select OLT and create Backup Task MOTOROLA and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings, LLC. All other trademarks are the property of their respective owners. © 2011 Motorola Mobility, Inc. All rights reserved. 3 Figure 2 – Enter Task Name and uncheck Delete backup option Figure 3 – Run the Backup Task MOTOROLA and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings, LLC. All other trademarks are the property of their respective owners. © 2011 Motorola Mobility, Inc. All rights reserved. 4 4. Remove the ASYSC System Controller from slot SYS-B. 5. Insert an ASYSD System Controller into slot SYS-B. After approximately three minutes, the following message should be displayed on the OLT CLI: System Controller Cards Hardware Mismatch6. After approximately five minutes, the following message should be displayed: Initial SYS Replication CompleteAfter the above message is displayed, remove the ASYSC System Controller from slot SYS-A. 7. Insert an ASYSD System Controller into slot SYS-A. Monitor the OLT CLI and watch for the following message to appear: Initial SYS Replication CompleteOnce the above message is displayed, both ASYSD System Controllers are operating in fully redundant mode. 8. In the OLT CLI, type the following command to have the ASYSD in slot SYS-A become the Active System Controller: AXS>set eqptsw manual to sys-a If any issues are encountered during the above procedure, please contact Motorola Customer Support at 1-800-MOT-WIRE. MOTOROLA and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings, LLC. All other trademarks are the property of their respective owners. © 2011 Motorola Mobility, Inc. All rights reserved. 5 ADDITIONAL INFORMATION: For International markets, please contact your Motorola Mobility representative on how to proceed. CONTACT INFORMATION: For assistance, please contact your Motorola Mobility Technical Assistance Center (TAC) at: North America: 1-800-668-9473

Phone (1-800-MOT-WIRE)

 

 

Vendor Motorola
Web Link www.motorola.com#http://www.motorola.com#
Date Entered 5/1/2018
You Tube Link
Type Of Article Support
Article ID 99


  Copyright    Lietz Development, Inc. 1996. All Rights Reserved.